| Trouble Starting
or Performing Routine Operations in
NCSS, PASS, or GESS If you experience
problems loading or performing routine operations in NCSS, PASS, or GESS
(e.g. runtime error 50003, a runtime
error 7, or an out-of-string space message, or any other message on
start up), the problem is likely due to one or more corrupt installation
files.
To fix the problem, do
the following:
1. Find the following files in your Windows\System32
Directory (or Windows/SysWOW64 if you are using a 64-bit Windows 7
computer) :
Csform32.ocx
Graphs32.ocx
H5ocx32.ocx
Vcf132.ocx
Vsocx32.ocx
2. Move each ocx file listed above from
the Windows\System32 (or Windows\SysWOW64) directory to another directory of your choice (such as OCX_Backup). Note, you must either move or delete the file since
the file will not be replaced unless it is not found in the Windows/System32
(or Windows\SysWOW64) directory. You can accomplish this using your Windows Explorer program.
3. Re-run the NCSS or PASS setup file
and choose "Repair" when prompted.
This should take care of your problem.